Release Note 2010/2

Version.1002

***************************************************
1: FPN/DEF mode
A bug was fixed. The specification is same as ver0711.

***************************************************
2: Recording interval
"0.5-125" seccond can be input into [Recording interval] in setup-box.

***************************************************
3: [preview] check-box in main window
ON/OFF of "previewing short movie after acquisition" can be available.
When this is OFF, the interval of programmed acquisition can be shorter.

***************************************************
4: Loop of sequence
"loop_beging" can be upto 800.

***************************************************
5: New Function
Function for sending MiCAM data from Ultima acquisition software
directly to BV_Ana without saving data in a data file.

---------------------------------------------------
(1) BV_Ana version. 1002

Select (Check) the [File]-[Accept data from Ultima exp] from the main menu of the BV_Ana.
Otherwise, an error occurs when data is transferred from the Ultima acquisition software.

The BV_Ana can show data that is transferred from the Ultima acquisition software.
In dual camera mode, two data is displayed separately.
After conforming data is displayed, push the [Save] button to save data in a file if needed.

---------------------------------------------------
(2) UltimaExp-ver1002/ UltiamExp-ver1002-dual

The [To BV_Ana] button is newly added below the [page selection] area.
This button allows acquired data to be sent to the BV_Ana.
Even after sending data to the BV_Ana, the Ultima acquisition software also
keeps acquired data.
In sequencer function, describe "send_ana" to execute this function.


(ATTN)
When the Ultima acquisition software is closed and then restarted,
set the [File]-[Accept data from Ultima exp] OFF, and then set it ON again
before pushing the [To BV_Ana] button on the Ultima acquisition software.

When many data are sent to the BV_Ana, or data that has large size of
frame number is sent to the BV_Ana, some error in receiving data may occur
because the BV_Ana cannot keep enough memory space.
In this case, close the error message and then, set the [File]-[Accept data from Ultima exp] OFF
in the BV_Ana. The Ultima acquisition software also shows error message.

To resolve this error, delete data on the canvas of the BV_Ana at first. Then,
set the [File]-[Accept data from Ultima exp] ON in the BV_Ana and execute the
[To BV_Ana] on the Ultima acquisition software.
***************************************************